OM-EL-ENVIROPAD-TC  
Thermometer With Built-in  
Data Logging and Graphing  
ORDERING INFORMATION  
OM-EL-ENVIROPAD-TC  
Thermometer with built-in  
Data Logging & Graphing  
Thermometer with  
Built-in Data Logging  
& Graphing  
OM-EL-ENVIROPAD-TC  
FEATURES  
• User selectable temperature °C or °F  
• Supplied with K-type probe  
• On-screen graphing  
• Two modes: data logging or spot measurement  
• User selectable high & low alarms  
• 2.8” color touch screen  
• Compatible with thermocouples type J, K, N, & T via mini  
thermocouple connection  
• Downloadable saved data via USB and viewed using  
Excel or similar spreadsheet packages  
• Internal rechargeable lithium polymer battery  
• Date & time function  
• Audible alarm  
• Removable protective boot for increased durability  
This robust easy to use handheld device takes and records temperature readings via the attached K--type probe supplied with the unit. A  
large touch screen, color display indicates temperature, maximum and minimum readings and will produce a graph of the data.  
It has two functions - Data Logging and Spot Measurement;  
1. When in Data Logging mode, it can be set up and left to take temperature readings at pre-determined intervals for a desired length of  
time. All readings are saved to a file with a date and time stamp in CSV format for up to 65,536 readings.  
2. When in Spot Measurement mode, the unit can be used as a thermometer to capture one-off temperature readings displayed on  
screen. This can be repeated for up to 65,536 readings per file.  
®
Data can be downloaded to PC via a USB connection and opened with Microsoft Excel .  
The unit is compatible with any J, K, N and T type thermocouple probes. The protective boot can be removed for cleaning and is dishwasher  
safe.  
Specifications  
Minimum  
Typical  
Maximum  
Unit  
V d.c.  
°C  
USB supply voltage  
4.5v  
-
5.5v  
Internal resolution  
-
0.1  
-
Data recording capacity (per recording)  
Hand unit operating temperature range  
Operating time (on a single charge)  
Displayable temperature (dependant on probe)  
Storage capacity  
-
65536  
+50 (+122)  
**  
readings  
°C (°F)  
hrs  
0 (+32)  
-
8
-100  
-
24*  
-80 to +1200  
+9999  
100  
°C  
-
files  
* Typical use: 1min recording rate & power-save  
** Depends on recording settings  
Warning - Do not exceed operating temperatures  
omega.com  
Specifications liable to change without prior warning  
Issue 01  
12/2012  
S.L  
Applies to OM-EL-EnviroPad-TC  
Page 1 of 2  
OM-EL-ENVIROPAD-TC  
Thermometer with Built-in Data Logging & Graphing  
HARDWARE  
UNIT  
• Battery: rechargeable via USB connection  
• LCD: color TFT touch-screen  
• Integrated memory for logged data  
• Single front-panel push-button used for power-switch. Single press=ON, press & hold=OFF.  
• 1x thermocouple connector (top of unit)  
• 1x micro USB Type B (bottom of unit) for connection of unit to PC via USB cable supplied.  
PROBE  
• Thermocouple probe: class 1 tolerance, 316 stainless steel probe  
• Sealed to IP66  
• Themocouple Type: K  
Specifications  
Minimum  
Typical  
Maximum  
Unit  
°C  
Probe Temperature Accuracy  
Probe Temperature Range*  
Handle Temperature Range  
-
+/- 1.5  
-
-180  
-10  
-
-
+1300  
+125  
°C  
°C  
* Short term measurement  
N.B. Any of the above hardware specifications may change without prior warning if new/suitable alternatives become available.  
DIMENSIONS  
All dimensions in mm (inches)  
(2.68)  
(0.75)  
omega.com  
Specifications liable to change without prior warning  
Issue 01  
10/2012  
S.L  
Applies to OM-EL-EnviroPad-TC  
Page 2 of 2  
WARRANTY/DISCLAIMER  
OMEGA ENGINEERING, INC., warrents this unit to be free of defects in materials and workmanship for  
a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month  
grace period to the normal one (1) year product warranty to cover handling and shipping time. This  
ensures that OMEGA’s customers receive maximum coverage on each product.  
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service  
Department will issue an Authorized Return (AR) number immediately upon phone or written request.  
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no  
charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser,  
including but not limited to mishandling, improper interfacing, operation outside of design limits,  
improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence  
of having been tampered with or shows evidence of having been damaged as a result of excessive  
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or  
other operating conditions outside of OMEGA’s control. Components in which wear is not warranted,  
include but are not limited to contact points, fuses, and triacs.  
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither  
assumes responsibility for any omissions or errors nor assumes liability for any damages that result  
from the use of its products in accordance with information provided by OMEGA, either verbal or  
written. OMEGA warrants only that the parts manufactured by the company will be as specified and  
free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND  
WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES  
INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE  
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are  
exclusive, and the total liability of OMEGA with respect to this order, whether based on contract,  
warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price  
of the component upon which liability is based. In no event shall OMEGA be liable for consequential,  
incidental or special damages.  
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a  
“Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2)  
in medical applications or used on humans. Should any Product(s) be used in or with any nuclear  
installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes  
no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally,  
purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever  
arising out of the use of the Product(s) in such a manner.  
RETURN REQUESTS/INQUIRIES  
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE  
RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN  
(AR) NUMBER FROM OMEGAS CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESS-  
ING DELAYS). The assigned AR number should then be marked on the outside of the return package and  
on any correspondence.  
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent  
breakage in transit.  
FOR WARRANTY RETURNS, please have  
the following information available BEFORE  
contacting OMEGA.  
1. Purchase order number which the product  
was PURCHASED,  
2. Model and serial number of the product  
under warranty, and  
FOR NON-WARRANTY RETURNS, consult  
OMEGA for current repair charges. Have the  
following information available BEFORE contacting  
OMEGA.  
1. Purchase Order number to cover the COST of  
the repair,  
2. Model and serial number of the product and  
3. Repair instructions and/or specific problems  
relative to the product.  
3. Repair instructions and/or specific problems  
relative to the product.  
OMEGA’s policy is to make running changes, not model changes, whenever an iimprovement is possible. This  
affords customers the latest technoogy and engineering.  
OMEGA is a registered tradrmark of OMEGA ENGINEERING, INC.  
© COPYRIGHT 2013 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied,  
photocopied, translated, or reduced to any electronic medium-readable form, in whole or in part, without the  
prior written consent of OMEGA ENGINEERING, INC.  
Where Do I Find Everything I Need for  
Process Measurement and Control?  
OMEGA... Of Course!  
SM  
Shop online at omega.com  
TEMPERATURE  
Thermocouple RTD & Thermister Probes Connectors, Panels & Assemblies  
Wire: Thermocouple, RTD & Thermister  
Calibrators & Ice Point References  
Recorders, Controllers & Process Monitors  
Infrared Pyrometers  
PRESSURE, STRAIN AND FORCE  
Transducers & Strain Gages  
Load Cells & Pressure Gages  
Displacement Transducers  
Instumentation & Accessories  
FLOW/LEVEL  
Rotameters Gas Mass Flowmeters & FlowComputers  
Air Velocity Indicators  
Turbine/Paddlewheel Systems  
Totalizers & Batch Controllers  
PH/CONDUCTIVITY  
pH Electrodes Testers & Accessories  
Benchtop/Laboratory Meters  
Controllers, Calibrators, Simulators & Pumps  
Industrial pH & Conductivity Equipment  
DATA ACQUISTION  
Data Acquistion & Engineering Software  
Communications-Based Acquistion Systems  
Plug-in Cards for Apple, IBM, & Compatibles  
Data Logging Systems  
Recorders, Printers, & Plotters  
HEATERS  
Heating Cable  
Cartridge & Strip Heaters  
Immersion & Band Heaters  
Flexible Heaters  
Laboratory Heaters  
ENVIRONMENTAL  
MONITORING AND CONTROL  
Metering & Control Instrumentation  
Refractometers  
Pumps & Tubing  
Air, Soil & Water Monitors  
Industrial Water & Wastewater Treatment  
pH Conductivity & Dissolved Oxygen Instruments  
M5238/0113  

Toshiba MK3019GAX User Manual
Tascam CD RW5000 User Manual
StarTechcom SAT2510U2E User Manual
Sony Ericsson T280A User Manual
Sony DRX 710UL User Manual
Sony CDX R3310 User Manual
Sherwood V 903 User Manual
Samsung S5200 User Manual
Philips USB CARICOMPUTER SJM2202 User Manual
Philips CT1628 User Manual